How To Change the Displayed Cell Size on an Aqua Rite SCG

This guide will help you to change the displayed cell size to match the installed cell size.The Aqua Rite SCG uses one of 4 Cell sizes - t-15, t-9, t-5, or t-3. The Cell size displayed in the Display diagnostic messages has to match the installed cell size to ensure proper operation including salt calculation. 

1. Push 8, Cell Size - With the Display showing its default value of "Average Salt Level". Push the Diagnostic Button 8 times to bring up the "Cell Size". It will read one of 4 values; t-3, t-5, t-9, or t-15. In this case the display is showing "t-9". The installed cell size is t-3. So we need to change this displayed value from t-9 to t-3. To make this change we will bump the value from t-9 to t-15 to t-3 as follows.

2. SLIDE MAIN SWITCH UP - Slide the Main Switch from Auto to Super Chlorinate. The display will show a cell size of "t-15".

3. SLIDE MAIN SWITCH DOWN - Slide the Main Switch back down to "Auto" to save the new cell size value.

4. SLIDE MAIN SWITCH UP - Slide the Main Switch from Auto to Super Chlorinate. The display will show a cell size of "t-3".

5. SLIDE MAIN SWITCH DOWN - Slide the Main Switch back down to "Auto" to save the new size change of t-3. So now the installed cell size matches the displayed cell size.

If you have any other questions about pool and spa products please do let us know - we are here to help! 